mhpmevent22
Machine Hardware Performance Counter 22 Control
Programmable hardware performance counter event selector and overflow/filtering control
Fields
OF
- Location
-
mhpmevent22[63]
- Description
-
Overflow status and interrupt disable.
The OF bit is set when the corresponding hpmcounter overflows, and remains set until written by software. Since hpmcounter values are unsigned values, overflow is defined as unsigned overflow of the implemented counter bits.
The OF bit is sticky; it stays set until explictly cleared by a CSR write.
A Local Counter Overflow Interrupt (LCOFI) is generated when OF is clear and mhpmcounter22 overflows.
- Type
RO |
Read-Only Field has a hardwired value that does not change. Writes to an RO field are ignored. |
- Reset value
-
0
MINH
- Location
-
mhpmevent22[62]
- Description
-
When set, mhpmcounter22 does not increment while the hart in operating in M-mode.
- Type
RO |
Read-Only Field has a hardwired value that does not change. Writes to an RO field are ignored. |
- Reset value
-
0
SINH
- Location
-
mhpmevent22[61]
- Description
-
When set, mhpmcounter22 does not increment while the hart in operating in (H)S-mode.
- Type
RO |
Read-Only Field has a hardwired value that does not change. Writes to an RO field are ignored. |
- Reset value
-
0
UINH
- Location
-
mhpmevent22[60]
- Description
-
When set, mhpmcounter22 does not increment while the hart in operating in U-mode.
- Type
RO |
Read-Only Field has a hardwired value that does not change. Writes to an RO field are ignored. |
- Reset value
-
0
VSINH
- Location
-
mhpmevent22[59]
- Description
-
When set, mhpmcounter22 does not increment while the hart in operating in VS-mode.
- Type
RO |
Read-Only Field has a hardwired value that does not change. Writes to an RO field are ignored. |
- Reset value
-
0
VUINH
- Location
-
mhpmevent22[58]
- Description
-
When set, mhpmcounter22 does not increment while the hart in operating in VU-mode.
- Type
RO |
Read-Only Field has a hardwired value that does not change. Writes to an RO field are ignored. |
- Reset value
-
0
EVENT
- Location
-
mhpmevent22[57:0]
- Description
-
Event selector for performance counter mhpmcounter22.
- Type
RO |
Read-Only Field has a hardwired value that does not change. Writes to an RO field are ignored. |
- Reset value
-
0
- Software write
-
This field has special behavior when written by software (e.g., through csrrw).
When software tries to write
csr_value
, the field will be written with the return value of the function below.if (ary_includes?<$array_size(HPM_EVENTS), 58>(HPM_EVENTS, csr_value.EVENT)) { return csr_value.EVENT; } else { return UNDEFINED_LEGAL_DETERMINISTIC; }