mhpmevent11h

Machine Hardware Performance Counter 11 Control, High half

Alias of mhpmevent11[63:32].

Introduced with the Sscofpmf extension. Prior to that, there was no way to access the upper 32-bits of mhpmevent#{hpm_num}.

Attributes

CSR Address

0x72b

Defining extension

  • Sscofpmf, version >= Sscofpmf@1.0.0

Length

32-bit

Privilege Mode

M

Format

mhpmevent11h format
Figure 1. mhpmevent11h format

Field Summary

Name Location Type Reset Value

OF

31

RO

0

MINH

30

RO

0

SINH

29

RO

0

UINH

28

RO

0

VSINH

27

RO

0

VUINH

26

RO

0

EVENT

25:0

RO

0

Fields

OF

Location

mhpmevent11h[31]

Description

Alias of mhpmevent11.OF.

Type

RO

Read-Only

Field has a hardwired value that does not change. Writes to an RO field are ignored.

Reset value

0

MINH

Location

mhpmevent11h[30]

Description

Alias of mhpmevent11.MINH.

Type

RO

Read-Only

Field has a hardwired value that does not change. Writes to an RO field are ignored.

Reset value

0

SINH

Location

mhpmevent11h[29]

Description

Alias of mhpmevent11.SINH.

Type

RO

Read-Only

Field has a hardwired value that does not change. Writes to an RO field are ignored.

Reset value

0

UINH

Location

mhpmevent11h[28]

Description

Alias of mhpmevent11.UINH.

Type

RO

Read-Only

Field has a hardwired value that does not change. Writes to an RO field are ignored.

Reset value

0

VSINH

Location

mhpmevent11h[27]

Description

Alias of mhpmevent11.VSINH.

Type

RO

Read-Only

Field has a hardwired value that does not change. Writes to an RO field are ignored.

Reset value

0

VUINH

Location

mhpmevent11h[26]

Description

Alias of mhpmevent11.VUINH.

Type

RO

Read-Only

Field has a hardwired value that does not change. Writes to an RO field are ignored.

Reset value

0

EVENT

Location

mhpmevent11h[25:0]

Description

High part of event selector for performance counter mhpmcounter11.

Type

RO

Read-Only

Field has a hardwired value that does not change. Writes to an RO field are ignored.

Reset value